Should We Use Redundant Supervisors?

I had a nice chat with Doug Gourlay from Arista during the Interop Las Vegas and he made an interesting remark along the lines of “in leaf-and-spine fabrics it doesn’t make sense to use redundant supervisors in switches – they cause more problems than they solve.”

As always, in the end it all depends on your environment and use case, but he definitely has a point; good engineering always works better than a heap of kludges.

read more see 7 comments

STP in Brocade VCS Fabric – an Interesting Solution after a Long Wait

Update 2021-01-03: The VCS Fabric idea was sent to the graveyard when Brocade Product Management discovered VXLAN and EVPN a few years before they were acquired by Extreme.

A few years ago I lambasted the lack of STP support in Brocade’s VCS fabric. It took Brocade over two years to solve the problem, but they finally came up with an interesting end-to-end solution.

Here are a few highlights; for more details read the Configuring STP-type Protocols section in Network OS Administrator Guide.

read more see 1 comments

Finally: Juniper Supports a Leaf-and-Spine Virtual Chassis

The recent Juniper product launch included numerous components, among them: a new series of data center switches (including a badly-needed spine switch), MetaFabric reference architecture (too meta for me at the moment – waiting to see the technical documentation beyond the whitepaper level), and (finally) a leaf-and-spine virtual chassis – Virtual Chassis Fabric.

read more see 4 comments

Configure physical firewalls based on VM groups? Sure, use DSE from Plexxi

Plexxi has an interesting problem. They have a shiny new solution that requires unorthodox approaches to network forwarding and allows them to implement potentially cool concepts like affinities (traffic engineering in disguise). They also need to sell these new concepts to the customers, and the first question I would ask after recovering from a hefty dose of cool-aid is "and how do I configure these affinities?"

read more see 1 comments

Migrating a cold VM into a foreign subnet

Moving a running VM into a foreign subnet is Mission Impossible due to stale ARP entries (anyone telling you otherwise is handwaving over a detail or two - maybe their VM doesn't communicate with other VMs in the same subnet), but it's entirely feasible to migrate a cold VM into a foreign subnet if you can fix IP routing. Here's how you can do the trick with Enterasys switches.

add comment

How Much Data Center Bandwidth Do You Really Need?

Networking vendors are quick to point out how the opaqueness (read: we don’t have the HW to look into it) of overlay networks presents visibility problems and how their favorite shiny gizmo (whatever it is) gives you better results (they usually forget to mention the lock-in that it creates).

Now let’s step back and ask a fundamental question: how much bandwidth do we need?

read more see 6 comments