Category: workshop

QFabric Part 2 – Control Plane Overview

2021-01-03: Even though QFabric was an interesting architecture (and reverse-engineering it was a fun intellectual exercise), it withered a few years ago. Looks like Juniper tried to bite off too much.

Like anyone else, I was pretty impressed with the QFabric hardware architecture when Juniper announced it, but remained way more interested in the control-plane aspects of QFabric. After all, if you want multiple switches to behave like a single device, you could either use Borg-like architecture with a single control plane entity, or implement some very clever tricks.

Nobody has yet demonstrated a 100-switch network with a single control plane (although the OpenFlow aficionados would make you believe it’s just around the corner), so it must have been something else.

read more see 1 comments

QFabric Part 1 – Hardware Architecture

2021-01-03: Even though QFabric was an interesting architecture (and reverse-engineering it was a fun intellectual exercise), it withered a few years ago. Looks like Juniper tried to bite off too much.

Juniper has finally released the technical documentation for the QFabric virtual switch and its components (QF/Node, QF/Interconnect and QF/Director). As expected, my speculations weren’t too far off – if anything, Juniper didn’t go far enough along those lines, but we’ll get there later.

The generic hardware architecture of the QFabric switching complex has been well known for quite a while (listening to the Juniper QFabric Packet Pushers Podcast is highly recommended) – here’s a brief summary:

read more see 28 comments

NVGRE – because one standard just wouldn’t be enough

2021-01-03: Looks like NVGRE died – even Microsoft walked away. There are tons of VXLAN implementations though. VMware and AWS are also using Geneve.

Two weeks after VXLAN (backed by VMware, Cisco, Citrix and Red Hat) was launched at VMworld, Microsoft, Intel, HP & Dell published NVGRE draft (Arista and Broadcom are cleverly sitting on both chairs) which solves the same problem in a slightly different way.

If you’re still wondering why we need VXLAN and NVGRE, read my VXLAN post (and the one describing how VXLAN, OTV and LISP fit together).

It’s obvious the NVGRE draft was a rushed affair, its only significant and original contribution to knowledge is the idea of using the lower 24 bits of the GRE key field to indicate the Tenant Network Identifier (but then, lesser ideas have been patented time and again). Like with VXLAN, most of the real problems are handwaved to other or future drafts.

read more add comment

Long-distance IRF Fabric: Works Best in PowerPoint

HP has commissioned an IRF network test that came to absolutely astonishing conclusions: vMotion runs almost twice as fast across two links bundled in a port channel than across a single link (with the other one being blocked by STP). The test report contains one other gem, this one a result of incredible creativity of HP marketing:

For disaster recovery, switches within an IRF domain can be deployed across multiple data centers. According to HP, a single IRF domain can link switches up to 70 kilometers (43.5 miles) apart.

You know my opinions about stretched cluster… and the more down-to-earth part of HP Networking (the people writing the documentation) agrees with me.

read more see 12 comments

Nexus 1000V LACP offload and the dangers of in-band control

2021-03-01: Nexus 1000v turned into abandonware long time ago, and is now officially a zombie (oops, EOL). However, the challenges they were facing with LACP offload are still worth pointing out to anyone advocating centralized control plane (stupidity formerly known as SDN).

A while ago someone sent me the following comment as part of a lengthy discussion focusing on Nexus 1000V: “My SE tells me that the latest 1000V release has rewritten the LACP code so that it operates entirely within the VEM. VSM will be out of the picture for LACP negotiations. I guess there have been problems.

If you’re not convinced you should be running LACP between the ESX hosts and the physical switches, read this one (and this one). Ready? Let’s go.

read more see 1 comments

VXLAN: MAC-over-IP-based vCloud networking

In one of my vCloud Director Networking Infrastructure rants I wrote “if they had decided to use IP encapsulation, I would have applauded.” It’s time to applaud: Cisco has just demonstrated Nexus 1000V supporting MAC-over-IP encapsulation for vCloud Director isolated networks at VMworld, solving at least some of the scalability problems MAC-in-MAC encapsulation has.

Nexus 1000V VEM will be able to (once the new release becomes available) encapsulate MAC frames generated by virtual machines residing in isolated segments into UDP packets exchanged between VEMs.

read more see 7 comments

BGP/IGP Network Design Principles

In the next few days, I'll write about some of the interesting topics we’ve been discussing during the last week’s fantastic on-site workshop with Ian Castleman and his team. To get us started, here’s a short video describing BGP/IGP network design principles. It’s taken straight from my Building IPv6 Service Provider Core webinar (recording), but the principles apply equally well to large enterprise networks.

read more add comment

Soft Switching Might not Scale, but We Need It

Following a series of soft switching articles written by Nicira engineers (hint: they are using a similar approach as Juniper’s QFabric marketing team), Greg Ferro wrote a scathing Soft Switching Fails at Scale reply.

While I agree with many of his arguments, the sad truth is that with the current state of server infrastructure virtualization we need soft switching regardless of the hardware vendors’ claims about the benefits of 802.1Qbg (EVB/VEPA), 802.1Qbh (port extenders) or VM-FEX.

read more see 7 comments

VM-FEX – not as convoluted as it looks

Update 2021-01-03: As far as I understand, VM-FEX died together with Cisco Nexus 1000v. I might be wrong and the zombie is still kicking...

Reading Cisco’s marketing materials, VM-FEX (the feature probably known as VN-Link before someone went on a FEX-branding spree) seems like a fantastic idea: VMs running in an ESX host are connected directly to virtual physical NICs offered by the Palo adapter and then through point-to-point virtual links to the upstream switch where you can deploy all sorts of features the virtual switch embedded in the ESX host still cannot do. As you might imagine, the reality behind the scenes is more complex.

read more see 8 comments

Stop reinventing the wheel and look around

Building large-scale VLANs to support IaaS services is every data center designer’s nightmare and the low number of VLANs supported by some data center gear is not helping anyone. However, as Anonymous Coward pointed out in a comment to my Building a Greenfield Data Center post, service providers have been building very large (and somewhat stable) layer-2 transport networks for years. It does seem like someone is trying to reinvent the wheel (and/or sell us more gear).

read more see 7 comments

Penultimate Hop Popping (PHP) demystified

I got an interesting question after writing the Asymmetric MPLS MTU Problem post:

Why does PHP happen only on directly-connected interfaces but not on other non-MPLS routes?

Obviously it’s time for a deep dive into Penultimate Hop Popping (PHP) mysteries (warning label: read the MPLS books if you plan to get seriously involved with MPLS).

read more see 4 comments

vSphere 5.0 new networking features: disappointing

I was sort of upset that my vacations were making me miss the VMware vSphere 5.0 launch event (on the other hand, being limited to half hour Internet access served with early morning cappuccino is not necessarily a bad thing), but after I managed to get home, I realized I hadn’t really missed much. Let me rephrase that – VMware launched a major release of vSphere and the networking features are barely worth mentioning (or maybe they’ll launch them when the vTax brouhaha subsides).

read more see 12 comments